TM 9-2350-311-34-1
10-1 WINTERIZATION KIT INSTALLATION — CONTINUED
a. Installation — Continued
59
60
61
62
63
64
NOTE
For vehicle circuitry incorporating the 3-position MASTER switch (one position
marked SLAVE), disconnect vehicle harness lead 459B at MASTER switch and
connect kit harness branch labeled 459B between MASTER switch and vehicle
harness lead 459B.
Steps 59 thru 61 apply to vehicles with engine model 7083-7396. Steps 62 thru 64
apply to vehicles with engine model 7083-7391.
Disconnect existing lead 459B (143) at rear of portable instrument panel (144) MASTER switch (145) (TM 9-
2350-311-20-1).
Connect branch lead 459B (146) of control box-to-driver’s compartment wiring harness (147) to rear of
MASTER switch (145).
Connect existing lead (143) to other lead of control box-to-driver’s compartment lead 459B (146) or existing
lead of 459B (143).
Disconnect bulkhead-to-portable instrument-panel wiring harness lead 486A (148) from GLOW PLUG switch
(153) behind driver’s instrument panel.
Connect winterization heater control box-to-driver’s compartment harness lead 400 (150) to bulkhead-to-
portable instrument panel wiring harness lead 486A (148).
Connect winterization heater control box-to-drivers compartment harness lead 400 (150) to GLOW PLUG
switch (149).